NSN 6665-01-515-3895

Part Details | AIR SAMPLER KIT

6665-01-515-3895 An assembly of equipment designed to collect samples of air suspected of being contaminated. May include electrically powered vacuum pump that draws a measured volume of air through a filter, tape or other such device, on which the sample(3) are collected and/or recorded to be later analyzed. The equipment may also be used with a telemetering device. Excludes ANALYZING KIT, CHEMICAL.

Alternate Parts: 6107348095 ITEM 33, 610-7348095 ITEM 33, 801012100, 801012-100, 6665-01-515-3895, 01-515-3895, 6665015153895, 015153895

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
66NOV 24, 200301-515-389533473 ( SAMPLER KIT, AIR )
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 6665-01-515-3895
Part Number Cage Code Manufacturer
610-7348095 ITEM 3333473KEYSTONE INDEX CARD CO
801012-10063882SENSIDYNE, LP
Technical Data | NSN 6665-01-515-3895
Characteristic Specifications
SPECIAL FEATURESFLOW RANGE:2-30 LVP; CONSTANT FLOW: 2-30 LPM AT PRESSURES UP TO 7 PSI; RUN TIME: 8 HR MIN.; OPERATING TEMP: -4 TO 113 DEG F; HUMIDITY RANGE: 0-95 PERCENT RH, NON-CONDENSING; ELECTRONIC PRESSURE DISPLAY; FULL FUNCTION TIMING PROGRAM; INSTANT-FAULT FUNCTION; PROGRAMMABLE MEMORY (UP TO 3 CUSTOM PROGRAMS); KEYPAD: ACCEPT, PROG, TIME/PRESS, RUN/HOLD; INDICATIORS: LLD DISPLAY, EXTERNAL ROTOMETER, INSTANT FAULT, LOW BATTERY; 4.3 INCHES W X 0.3 H X 7.5 D; 12VDC AT 3.4 AMP
PART NAME ASSIGNED BY CONTROLLING AGENCYAIRCON-2 DC-PROGRAMMABLE HIGH VOLUME AIR SAMPLER