NSN 6665-01-495-0648

Part Details | AUTOMATIC GAS ALARM

6665-01-495-0648 A device which detects the presence of hazardous gases or vapors, toxic explosives, and/or sounds an alarm, and/or lights or flashes lights of distinctive color when the concentration reaches a dangerous level. Excludes ALARM, CHEMICAL AGENT, AUTOMATIC.

Alternate Parts: AA59707, A-A-59707, LD182.00M, LD18-2.00M, 6665-01-495-0648, 01-495-0648, 6665014950648, 014950648

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
66MAR 05, 200201-495-064828625 ( ALARM, GAS, AUTOMATIC )
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 6665-01-495-0648
Part Number Cage Code Manufacturer
A-A-5970758536FEDERAL COMMERCIAL ITEM DESCRIPTIONPROMULGATED BY GENERAL SERVICES
LD18-2.00M55099INTERSCAN CORPORATION
Technical Data | NSN 6665-01-495-0648
Characteristic Specifications
MEDIA DETECTED EXPLOSIVE GAS AND COMBUSTIBLE GAS AND VOLATILE VAPOR
USAGE DESIGN DOMESTIC AND FIELD AND INDUSTRIAL AND SHIPBOARD
ELECTRICAL POWER SOURCE RELATIONSHIP OPERATING
AC VOLTAGE RATING105.0 VOLTS MINIMUM AND 240.0 VOLTS MAXIMUM
FREQUENCY RATING50.0 HERTZ MINIMUM AND 60.0 HERTZ MAXIMUM
PHASE SINGLE
SPECIFIC USAGE DESIGNMONITOR LEVEL OF H-70 (70% HYDRAZINE, 30% WATER) VAPORS, AND SOUND ALARM IF IT REACHES HAZARDOUS LEVELS
INDICATOR TYPEDP ANY ACCEPTABLE
DESIGN TYPE NONTRIPOD MOUNTING
CUBIC MEASURE4000.000 CUBIC INCHES
UNPACKAGED UNIT WEIGHT40.000 POUNDS
FUNCTIONAL DESCRIPTIONCONTINOUSLY DETECTS/MONITORS TOXIC AMOUNTS OF HYDRAZINE VAPORS IN OPEN & ENCLOSED AREAS. INTENDED FOR BENCH TOP USE TO MONITOR THE LEVEL OF HYDRAZINE PRESENT IN WORKING ENVIRONMENTS WHEN SERVICING, MAINTAINING, & OVERHAULING AIRCRAFT COMPONENTS & ASSEMBLIES IN AN IMMEDIATE WORK AREA WHERE EXPOSURE TO HYDRAZINE VAPORS EXIST
REFERENCE DATA AND LITERATURECID A-A-59707
PART NAME ASSIGNED BY CONTROLLING AGENCYDETECTOR/MONITOR, HYDRAZINE