NSN 6665-01-399-5940

Part Details | RADIACMETER

6665-01-399-5940 An item specifically designed to detect and measure radioactive energy; indicates directly. It may or may not include the function of a radiac computer.

Alternate Parts: PD10, PD-10, PD10, PD-10, 6665-01-399-5940, 01-399-5940, 6665013995940, 013995940

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
66NOV 30, 199401-399-594007833 ( RADIACMETER )
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 6665-01-399-5940
Part Number Cage Code Manufacturer
PD-1032101LEIDOS, INC.
PD-1052302LEIDOS, INC.DIV RESEARCH AND DEVELOPMENT
Technical Data | NSN 6665-01-399-5940
Characteristic Specifications
RADIATION RANGE PER HOUR+0.0 TO +999.0 MILLIROENTGENS
INDICATOR TYPEDG ANY ACCEPTABLE AND DL ANY ACCEPTABLE
DETECTING ELEMENT TYPEB ANY ACCEPTABLE
INTERNAL BATTERY ACCOMMODATION INCLUDED
PORTABILITY PORTABLE
CARRYING CASE PROVIDED
CASE MATERIAL PLASTIC
OVERALL WIDTH48.0 MILLIMETERS NOMINAL
OVERALL HEIGHT72.0 MILLIMETERS NOMINAL
MOUNTING METHODR$DLS
SPECIAL FEATURESINCLUDES VISUAL AND AUDIO ALARMS;LCD DISPLAY AND LOW BATTERY INDICATOR;POWER STANDARD AA BATTERIES; DIGITAL CALIBRATION; MEETS DROP TEST OF PARAGRAPH 3.13 OF ANSI N13.27 1981; SENSOR MINITURE GEIGER-MUELLER TUBE ENERGY COMPENSATED; WEIGHT LESS THAN 90 GRAMS WITH BATTERY; DESIGNED TO BE WORN CLIPPEDTO POCKET
SUPPLEMENTARY FEATURESMANUFACTURERS NAME: ALARMING DOSIMETER