NSN 6665-01-353-3785
Part Details | GAS DETECTOR
6665-01-353-3785 A device specifically designed for the detection and/or evaluation and indication of hazardous gases.
Alternate Parts: F91K164, 9112280, 91-12-2-80, 8101381, 81 01381, 80001381, 800-01381, 6665-01-353-3785, 01-353-3785, 6665013533785, 013533785
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
66 | FEB 10, 1992 | 01-353-3785 | 37401 ( DETECTOR, GAS ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 6665-01-353-3785
Part Number | Cage Code | Manufacturer |
---|---|---|
F91K164 | 66735 | AIR FORCE MEDICAL LOGISTICS OFFICE |
91-12-2-80 | 66735 | AIR FORCE MEDICAL LOGISTICS OFFICE |
8101381 | 7T555 | DEVCO ENGINEERING CO |
81 01381 | 53833 | DRAEGER SAFETY, INC. |
800-01381 | 55659 | SKC, INC. |
Technical Data | NSN 6665-01-353-3785
Characteristic | Specifications |
---|---|
DETECTING ELEMENT TYPE | F ANY ACCEPTABLE |
DETECTING ELEMENT DETACHABILITY | INTEGRAL |
PREAMPLIFIER | NOT INCLUDED |
PHOTOMULTIPLIER | NOT INCLUDED |
CASE MATERIAL | GLASS |
OVERALL LENGTH | 5.000 INCHES NOMINAL |
OVERALL DIAMETER | 0.833 INCHES NOMINAL |
SPECIAL FEATURES | GRADUATED,DIRECT-READING GLASS DIFFUSION TUBE; CARBON DIOXIDE SAMPLES ARE TAKEN AT A CONSTANT RATE AND DIFFUSED INTO THE TUBE WHERE THEY UNDERGO A COLORIMETRIC REACTION; MEASURES TIME-WEIGHTED AVERAGE CONCENTRATIONS FOR PERIODS UP TO 8 HOURS; ON SPOT RESULTS; NO INSTRUMENTS NEEDED; 500 TO 20,000 PPM X H; 65 TO 2,500 PPM MAX DURING 8 HOURS |