NSN 6115-00-376-6985
Part Details | DIESEL ENGINE GENERATOR SET
6115-00-376-6985 A generator set using a diesel engine as the prime mover. Excludes GENERATOR SET, DIESEL ENGINE, TRAILER MOUNTED.
Alternate Parts: 6903, MILG10327BTYPE2CLASSA, 6903, 6115-00-376-6985, 00-376-6985, 6115003766985, 003766985
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
61 | JAN 01, 1963 | 00-376-6985 | 00476 ( GENERATOR SET, DIESEL ENGINE ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 6115-00-376-6985
Part Number | Cage Code | Manufacturer |
---|---|---|
6903 | 24617 | GENERAL MOTORS CORP |
MILG10327BTYPE2CLASSA | 81349 | MILITARY SPECIFICATIONSPROMULGATED BY MILITARY |
6903 | 72582 | MTU AMERICA INC. |
Technical Data | NSN 6115-00-376-6985
Characteristic | Specifications |
---|---|
CURRENT TYPE | AC |
AC WATTAGE RATING | 60.0 KILOWATTS AND 60.0 KILOWATTS AND 50.0 KILOWATTS |
FREQUENCY RATING | 50.0 HERTZ MINIMUM AND 60.0 HERTZ MAXIMUM |
PHASE | THREE AND THREE AND THREE |
LINE TO LINE VOLTAGE IN VOLTS | B416.0$$B208.0$$B416.0 |
LINE TO NEUTRAL VOLTAGE IN VOLTS | B240.0$$B120.0$$B240.0 |
POWER FACTOR IN PERCENT | B0.8$$B0.8$$B0.8 |
EXCITOR TYPE | SEPARATELY EXCITED |
EXCITOR | INCLUDED |
TEMP RISE RATING IN DEG CELSIUS FOR CONTINUOUS OPERATION | 75.000 |
PRIME MOVER COOLING MEDIUM | LIQUID |
COOLING METHOD | RADIATOR |
PRIME MOVER STARTING METHOD | C ANY ACCEPTABLE |
CRANKING VOLTAGE IN VOLTS | 24.000 |
AUTOMATIC STARTING FEATURE | NOT PROVIDED |
MOUNTING TYPE | SKID |
OVERALL LENGTH | 120.000 INCHES NOMINAL |
OVERALL WIDTH | 40.000 INCHES NOMINAL |
OVERALL HEIGHT | 76.000 INCHES NOMINAL |
RADIO INTERFERENCE SUPPRESSION | INCLUDED |
WINTERIZATION FEATURE | INCLUDED |
HOUSING TYPE | INCLOSED |
INCLOSURE TYPE | FULLY INCLOSED |