NSN 6110-00-068-8491

Part Details | DISTRIBUTION BOX

6110-00-068-8491 An enclosure which includes mounts, and protects such items as switches, circuit breakers, jacks, fuseholders, connectors, terminals and/or terminal boards, resistors, capacitors, transformers, and the like. It is primarily designed to distribute electrical power from one or more primary power source(s) such as generator(s) and battery(ies) to one or more electrical and/or electronic item(s). It may include a cover or door. For enclosures which include only circuit breakers, switches, jacks, fuseholders, terminals and/or terminal boards, see CIRCUIT BREAKER BOX; SWITCH BOX; JACK BOX; FUSE BOX and TERMINAL BOX. For enclosure primarily designed to interconnect two or more electrical and/or electronic items, except primary power source(s) see INTERCONNECTING BOX. For empty boxes which are designed to mount, but do not include electrical devices such as switches, jacks, fuseholders, terminals and/or terminal boards, see JUNCTION BOX. See also INTERCONNECTING CABINET; CONTROL (as modified); PANEL (1) (as modified); RELAY ASSEMBLY; PANEL, POWER DISTRIBUTION; SWITCHBOARD (as modified) and PANEL, FUSE. Excludes CONNECTOR-SWITCH.

Alternate Parts: 11654980, 11590881, 6110-00-068-8491, 00-068-8491, 6110000688491, 000688491

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
61JAN 25, 197200-068-849119735 ( DISTRIBUTION BOX )
REFERENCE DRAWINGS & PICTURES

4 POINT-RECTANGULAR

DISTRIBUTION BOX | 6110-00-068-8491, 000688491
Cross Reference | NSN 6110-00-068-8491
Part Number Cage Code Manufacturer
1165498019207U S ARMY TANK AUTOMOTIVE COMMANDAMSTA-IM-MM
1159088119207U S ARMY TANK AUTOMOTIVE COMMANDAMSTA-IM-MM
Technical Data | NSN 6110-00-068-8491
Characteristic Specifications
OVERALL DEPTH7.350 INCHES NOMINAL
OVERALL HEIGHT13.510 INCHES NOMINAL
OVERALL WIDTH8.870 INCHES NOMINAL
MATERIAL ALUMINUM ALLOY
SURFACE TREATMENT ENAMEL
ENTRANCE TYPE AND QUANTITY5 ELECTRICAL CONNECTOR
MOUNTING METHOD THREADED HOLE
STANDARD MOUNTING PATTERN DESIGNATOR 4 POINT-RECTANGULAR
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH12.000 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO HEIGHT6.188 INCHES NOMINAL
MOUNTING FACILITY THREAD SIZE0.250-20 UNC