NSN 6105-00-500-1388

Part Details | DIRECT CURRENT MOTOR

6105-00-500-1388 A motor which is designed for operation from a direct current source. Excludes MOTOR, ENGINE STARTER, ELECTRICAL. See also MOTOR, CONTROL.

Alternate Parts: W8960264, 31A180414WM956EEY6, 31A1804-14WM956EEY6, 31A1804, MILM17413SERVICEA, 6105-00-500-1388, 00-500-1388, 6105005001388, 005001388

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
61JAN 01, 196300-500-138816350 ( MOTOR, DIRECT CURRENT )
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 6105-00-500-1388
Part Number Cage Code Manufacturer
W896026403497GENERAL ELECTRIC COOUTDOOR BREAKER BUSINESS SECTION
31A1804-14WM956EEY603497GENERAL ELECTRIC COOUTDOOR BREAKER BUSINESS SECTION
31A180403497GENERAL ELECTRIC COOUTDOOR BREAKER BUSINESS SECTION
MILM17413SERVICEA81349MILITARY SPECIFICATIONSPROMULGATED BY MILITARY
Technical Data | NSN 6105-00-500-1388
Characteristic Specifications
OVERALL WIDTH17.875 INCHES
OVERALL HEIGHT23.312 INCHES
MOUNTING METHOD FIXED BASE
MOUNTING FACILITY TYPE AND QUANTITY4 UNTHREADED HOLE
NOMINAL CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH10.750 INCHES
NOMINAL CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH14.250 INCHES
INCLOSURE FEATURE DRIPPROOF-15 DEG
INCLOSURE SPECIFICATION MIL-STD-108
FRAME SIZE DESIGNATION75
CURRENT RATING METHOD LOAD
WINDING TYPE COMPOUND WOUND
DUTY CYCLE INTERMITTENT
TIME INTERVAL1.0 HOURS MAXIMUM ON
TEMP RATING45.0 AMBIENT DEG CELSIUS AND 40.0 OPERATING DEG CELSIUS
COOLING METHOD SELF-VENTILATED
ROTOR SPEED RATING IN RPM1800.0 SINGLE FULL LOAD
FEATURES PROVIDED VERTICAL MOUNTING POSITION