NSN 6105-00-260-6682
Part Details | DIRECT CURRENT MOTOR
6105-00-260-6682 A motor which is designed for operation from a direct current source. Excludes MOTOR, ENGINE STARTER, ELECTRICAL. See also MOTOR, CONTROL.
Alternate Parts: 2647703, 26477-03, 2647702, 26477-02, A100A4, A100A4, MILM8609, ZAP18FAAND200S, A100A4, 6105-00-260-6682, 00-260-6682, 6105002606682, 002606682
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
61 | JAN 01, 1963 | 00-260-6682 | 16350 ( MOTOR, DIRECT CURRENT ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 6105-00-260-6682
Part Number | Cage Code | Manufacturer |
---|---|---|
26477-03 | 35351 | GE AVIATION SYSTEMS LLC |
26477-02 | 35351 | GE AVIATION SYSTEMS LLC |
A100A4 | 35351 | GE AVIATION SYSTEMS LLC |
A100A4 | 31435 | LUCAS AEROSPACE POWER EQUIPMENTCORPORATION |
MILM8609 | 81349 | MILITARY SPECIFICATIONSPROMULGATED BY MILITARY |
ZAP18FAAND200S | 57655 | NAUTEL MAINE INC. |
A100A4 | 3CPE0 | SAFRAN POWER USA, LLC |
Technical Data | NSN 6105-00-260-6682
Characteristic | Specifications |
---|---|
OVERALL LENGTH | 5.002 INCHES |
OVERALL WIDTH | 1.562 INCHES |
OVERALL HEIGHT | 2.062 INCHES |
MOUNTING METHOD | PAD |
MOUNTING FACILITY TYPE AND QUANTITY | 4 UNTHREADED HOLE |
NOMINAL CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.250 INCHES |
NOMINAL CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO HEIGHT | 1.250 INCHES |
INCLOSURE FEATURE | TOTALLY INCLOSED |
INCLOSURE SPECIFICATION | COMMERCIAL |
CURRENT RATING METHOD | LOAD |
WINDING TYPE | SERIES WOUND |
DUTY CYCLE | INTERMITTENT |
TIME INTERVAL | 3.0 MINUTES MAXIMUM ON AND 17.0 MINUTES MINIMUM OFF |
TEMP RATING | -50.0 OPERATING DEG CELSIUS AND 70.0 OPERATING DEG CELSIUS |
COOLING METHOD | NONVENTILATED |
ROTOR SPEED RATING IN RPM | 20000.0 SINGLE FULL LOAD |
FEATURES PROVIDED | HORIZONTAL MOUNTING POSITION AND VERTICAL MOUNTING POSITION |