NSN 5985-00-086-7295

Part Details | ELECTRICAL DUMMY LOAD

5985-00-086-7295 A specific electrical element or set of electrical elements that are connected together to form a fixed arrangement and used as a substitute load for terminating an electrical circuit. A dummy load contains all the essential electrical characteristics necessary to terminate the circuit but does not function in the same manner as the load which it replaces. Examples are resistors used to replace antennas, batteries, loudspeakers, or the like. Includes single port terminations of twin lead, coaxial and waveguide transmission lines as low power terminations of a section of a transmission system in a specified manner. Includes dummy loads when arranged in a group or bank. Excludes power absorbers. See also LOAD BANK, ELECTRICAL.

Alternate Parts: SMB422333, SM-B-422333, SMB422333, SM-B-422333, 5985-00-086-7295, 00-086-7295, 5985000867295, 000867295

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
59JAN 01, 196300-086-729500335 ( DUMMY LOAD, ELECTRICAL )
REFERENCE DRAWINGS & PICTURES

COAXIAL MOUNTED

DUMMY LOAD,ELECTRIC | 5985-00-086-7295, 000867295
Cross Reference | NSN 5985-00-086-7295
Part Number Cage Code Manufacturer
SM-B-42233380063US ARMY COMMUNICATIONS &ELECTRONICS MATERIEL READINESS
SM-B-42233320723VALCORE MANUFACTURING LLCDBA USE CAGE CODE 04YE2 FOR
Technical Data | NSN 5985-00-086-7295
Characteristic Specifications
STYLE DESIGNATOR COAXIAL MOUNTED
POWER RATING0.125 WATTS AVERAGE
IMPEDANCE RATING IN OHMS47.0 NOMINAL
TERMINATION TYPE CONNECTION COAXIAL
COAXIAL CONNECTOR SERIES DESIGNATION BNC
CONNECTOR END DESIGN FEMALE
COOLING METHOD SELF-COOLED
OPERATING POSITION ALL POSITIONS
SPECIAL FEATURESCONNECTOR THREADED 0.375-32; MOUNTED WITH NUT
RF CONNECTOR CHANGING FEATURE NOT INCLUDED
FRAGILITY FACTOR MODERATELY RUGGED
FSC APPLICATION DATAANTENNAS,WAVEGUIDES AND RELATED EQUIP.