NSN 5985-00-073-0595

Part Details | ELECTRICAL DUMMY LOAD

5985-00-073-0595 A specific electrical element or set of electrical elements that are connected together to form a fixed arrangement and used as a substitute load for terminating an electrical circuit. A dummy load contains all the essential electrical characteristics necessary to terminate the circuit but does not function in the same manner as the load which it replaces. Examples are resistors used to replace antennas, batteries, loudspeakers, or the like. Includes single port terminations of twin lead, coaxial and waveguide transmission lines as low power terminations of a section of a transmission system in a specified manner. Includes dummy loads when arranged in a group or bank. Excludes power absorbers. See also LOAD BANK, ELECTRICAL.

Alternate Parts: 2382920, 2270715, 5985-00-073-0595, 00-073-0595, 5985000730595, 000730595

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
59JAN 01, 196300-073-059500335 ( DUMMY LOAD, ELECTRICAL )
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 5985-00-073-0595
Part Number Cage Code Manufacturer
238292056232LOCKHEED MARTIN CORPORATIONDBA LOCKHEED MARTIN
227071510001NAVAIR AND NAVSEA MANAGEDORIGINAL DESIGN ACTIVITY DWG NOT
Technical Data | NSN 5985-00-073-0595
Characteristic Specifications
FREQUENCY RANGE RATING+5.400 TO +5.900 GIGAHERTZ
POWER RATING300.000 KILOWATTS PEAK AND 600.000 WATTS AVERAGE
VOLTAGE STANDING WAVE RATIO1.20
VOLTAGE STANDING WAVE RATIO FREQUENCY RANGE+5.400 TO +5.900 GIGAHERTZ
TERMINATION TYPE WAVEGUIDE FLANGE
INTERNAL OPERATING PRESSURE40.0 POUNDS PER SQUARE INCH GAGE
COOLING METHOD SELF-COOLED
OPERATING POSITION ALL POSITIONS
FRAGILITY FACTOR MODERATELY RUGGED
FSC APPLICATION DATAANTENNAS,WAVEGUIDES,AND RELATED EQUIPMENT