NSN 5985-00-033-9540
Part Details | ELECTRICAL DUMMY LOAD
5985-00-033-9540 A specific electrical element or set of electrical elements that are connected together to form a fixed arrangement and used as a substitute load for terminating an electrical circuit. A dummy load contains all the essential electrical characteristics necessary to terminate the circuit but does not function in the same manner as the load which it replaces. Examples are resistors used to replace antennas, batteries, loudspeakers, or the like. Includes single port terminations of twin lead, coaxial and waveguide transmission lines as low power terminations of a section of a transmission system in a specified manner. Includes dummy loads when arranged in a group or bank. Excludes power absorbers. See also LOAD BANK, ELECTRICAL.
Alternate Parts: 150A426G05, WEA71, WE-A71, 150A426G05, 150A426G05, 5985-00-033-9540, 00-033-9540, 5985000339540, 000339540
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | JAN 01, 1963 | 00-033-9540 | 00335 ( DUMMY LOAD, ELECTRICAL ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 5985-00-033-9540
Part Number | Cage Code | Manufacturer |
---|---|---|
150A426G05 | 00929 | MICROLAB/FXR |
WE-A71 | 00929 | MICROLAB/FXR |
150A426G05 | 97942 | NORTHROP GRUMMAN SYSTEMS CORPORATIONDIV NORTHROP GRUMMAN SYSTEMS |
150A426G05 | 79500 | WESTINGHOUSE ELECTRIC CORP |
Technical Data | NSN 5985-00-033-9540
Characteristic | Specifications |
---|---|
FREQUENCY RANGE RATING | +2.320 TO +2.680 GIGAHERTZ |
POWER RATING | 200.000 WATTS AVERAGE AND 100.000 KILOWATTS PEAK |
VOLTAGE STANDING WAVE RATIO | 1.10 |
VOLTAGE STANDING WAVE RATIO FREQUENCY RANGE | +2.320 TO +2.680 GIGAHERTZ |
TERMINATION TYPE | WAVEGUIDE FLANGE |
COOLING METHOD | SELF-COOLED |
OPERATING POSITION | ALL POSITIONS |
FRAGILITY FACTOR | MODERATELY RUGGED |
FSC APPLICATION DATA | ANTENNAS,WAVEGUIDES,AND RELATED EQUIPMENT |