NSN 5950-00-059-2844

Part Details | POWER TRANSFORMER

5950-00-059-2844 A transformer consisting of one or more primary winding(s) and one or more secondary winding(s). It may be designed for direct connection to an alternating current source for purposes of changing the secondary volts and amperes or designed to eliminate metallic interconnection between circuits in an overall one to one voltage ratio, with or without additional output windings, or items designed to automatically maintain a constant output voltage within specified limits under varying input or load conditions. Also includes items having a provision for mechanically changing the turns ratio or inductive coupling in progressive increments by means of voltage taps, ratio adjuster, or devices oe similar design. For transformers having winding(s) common to both input and output circuits, see TRANSFORMER (1), POWER, AUTOTRANSFORMER. Excludes TRANSFORMER (1), PULSE.

Alternate Parts: 10511893, M6336, M-6336, 59T11C1499, 10511893, 5950-00-059-2844, 00-059-2844, 5950000592844, 000592844

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
59JAN 01, 196100-059-284432496 ( TRANSFORMER, POWER )
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 5950-00-059-2844
Part Number Cage Code Manufacturer
1051189319204ARMY, UNITED STATES DEPARTMENT OFTHE
M-633693346COBHAM ADVANCED ELECTRONIC SOLUTIONSINC.
59T11C149959523NORTH ERIE ELECTRONICS, INCDBA WESTERN RESERVE TOOL MACHINE
1051189310587NYCO TRANSFORMER CO
Technical Data | NSN 5950-00-059-2844
Characteristic Specifications
TERMINAL TYPE AND QUANTITY16 TAB, SOLDER LUG
INCLOSURE TYPE HERMETICALLY SEALED
BODY LENGTH3.940 INCHES NOMINAL
BODY HEIGHT4.310 INCHES NOMINAL
BODY WIDTH3.380 INCHES NOMINAL
RELIABILITY INDICATOR NOT ESTABLISHED
SPECIAL FEATURES6 SECONDARIES
MAXIMUM OPERATING TEMP100.0 DEG CELSIUS