NSN 5925-00-910-7485

Part Details | CIRCUIT BREAKER

5925-00-910-7485 A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see RELAY (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see RELAY-SWITCH. Excludes CIRCUIT BREAKER BOX and magneto "breaker" assemblies. See also SWITCH (as modified); and CONTROLLER.

Alternate Parts: 10167899, 5925-00-910-7485, 00-910-7485, 5925009107485, 009107485

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
59JAN 01, 196000-910-748500136 ( CIRCUIT BREAKER )
REFERENCE DRAWINGS & PICTURES

RECTANGULAR DIMENSIONAL ENVELOPE

CIRCUIT BREAKER | 5925-00-910-7485, 009107485
Cross Reference | NSN 5925-00-910-7485
Part Number Cage Code Manufacturer
1016789918876U S ARMY AVIATION AND MISSILECOMMAND
Technical Data | NSN 5925-00-910-7485
Characteristic Specifications
POLE QUANTITY1
TERMINAL TYPE AND QUANTITY2 COMPRESSION
RESET METHOD MANUAL
BODY STYLE RECTANGULAR DIMENSIONAL ENVELOPE
CASE MATERIAL PLASTIC
MOUNTING FACILITY TYPE AND QUANTITY4 THREADED HOLE
MAIN CONTACT TRIPPING MECHANISM TYPE TRIP FREE
OVERALL LENGTH1.954 INCHES MINIMUM AND 1.984 INCHES MAXIMUM
OVERALL HEIGHT0.989 INCHES MINIMUM AND 0.997 INCHES MAXIMUM
OVERALL WIDTH1.329 INCHES MINIMUM AND 1.359 INCHES MAXIMUM
THREAD SERIES DESIGNATOR UNC
NOMINAL THREAD SIZE0.138 INCHES
THREAD QUANTITY PER INCH32
MANUAL ACTUATOR TYPE AND QUANTITY1 PUSH BUTTON
ACTUATOR FUNCTION RESET
ACTUATOR POSITION DESIGNATION AT POLE ONE
AUXILIARY SWITCH FUNCTION AND QUANTITY1 ALARM
SWITCH LOCATION AND POSITION DESIGNATION INTERNAL AT POLE ONE
SWITCH CONTACT ARRANGEMENT SINGLE POLE, DOUBLE THROW
SWITCH CURRENT RATING AND TYPE IN AMPS1.0 AC AND 1.0 DC
SWITCH VOLTAGE RATING AND TYPE IN VOLTS115.0 AC AND 50.0 DC
SWITCH TERMINAL TYPE PIN
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED GENERAL PURPOSE
STORAGE TYPEE ANY ACCEPTABLE
PRECIOUS MATERIAL SILVER
PRECIOUS MATERIAL AND LOCATIONCONTACT SURFACES SILVER
FRAGILITY FACTOR MODERATELY RUGGED