NSN 5925-00-223-1842

Part Details | CIRCUIT BREAKER

5925-00-223-1842 A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see RELAY (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see RELAY-SWITCH. Excludes CIRCUIT BREAKER BOX and magneto "breaker" assemblies. See also SWITCH (as modified); and CONTROLLER.

Alternate Parts: 300558, 30055-8, 5925-00-223-1842, 00-223-1842, 5925002231842, 002231842

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
59MAY 11, 197300-223-184200136 ( CIRCUIT BREAKER )
REFERENCE DRAWINGS & PICTURES

SINGLE POLE TYPE

CIRCUIT BREAKER | 5925-00-223-1842, 002231842
Cross Reference | NSN 5925-00-223-1842
Part Number Cage Code Manufacturer
30055-813445COLE HERSEE COMPANY
Technical Data | NSN 5925-00-223-1842
Characteristic Specifications
POLE QUANTITY1
TERMINAL TYPE AND QUANTITY2 THREADED STUD
RESET METHOD AUTOMATIC
BODY STYLE SINGLE POLE TYPE
CASE MATERIAL METAL
MOUNTING FACILITY TYPE AND QUANTITY2 TERMINAL
OVERALL LENGTH50.8 MILLIMETERS NOMINAL
BODY WIDTH19.81 MILLIMETERS NOMINAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH17.14 MILLIMETERS MINIMUM AND 17.27 MILLIMETERS MAXIMUM
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH31.75 MILLIMETERS NOMINAL
MOUNTING SURFACE TO TERMINAL END DISTANCE34.97 MILLIMETERS NOMINAL
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED HERMETICALLY SEALED
STORAGE TYPEE ANY ACCEPTABLE
FRAGILITY FACTOR MODERATELY RUGGED