NSN 5925-00-057-6762

Part Details | CIRCUIT BREAKER

5925-00-057-6762 A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see RELAY (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see RELAY-SWITCH. Excludes CIRCUIT BREAKER BOX and magneto "breaker" assemblies. See also SWITCH (as modified); and CONTROLLER.

Alternate Parts: AM12MG615A250V60CPSCURVE, AM12MG6-15A250V60CPSCURVE, 3103105, 310310-5, 1063008293, 10630082-93, 1063008293, 10630082-93, 1063008293, 10630082-93, 5925-00-057-6762, 00-057-6762, 5925000576762, 000576762

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
59JAN 01, 196100-057-676200136 ( CIRCUIT BREAKER )
REFERENCE DRAWINGS & PICTURES

SINGLE POLE TYPE

CIRCUIT BREAKER | 5925-00-057-6762, 000576762
Cross Reference | NSN 5925-00-057-6762
Part Number Cage Code Manufacturer
AM12MG6-15A250V60CPSCURVE74193EATON CORPHEINEMANN PRODUCTS
310310-500752EDO LLCDIV ANTENNA PRODUCTS
10630082-9304939LOCKHEED MARTIN CORPORATIONDBA LOCKHEED MARTIN
10630082-9338597LOCKHEED MARTIN CORPORATIONDBA LOCKHEED MARTIN
10630082-9318876U S ARMY AVIATION AND MISSILECOMMAND
Technical Data | NSN 5925-00-057-6762
Characteristic Specifications
POLE QUANTITY1
TERMINAL TYPE AND QUANTITY2 THREADED STUD
RESET METHOD MANUAL
BODY STYLE SINGLE POLE TYPE
CASE MATERIAL PLASTIC
MOUNTING FACILITY TYPE AND QUANTITY2 THREADED HOLE
MAIN CONTACT TRIPPING MECHANISM TYPE TRIP FREE
BODY LENGTH2.500 INCHES MINIMUM AND 2.530 INCHES MAXIMUM
BODY WIDTH0.740 INCHES MINIMUM AND 0.760 INCHES MAXIMUM
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH1.930 INCHES MINIMUM AND 1.950 INCHES MAXIMUM
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH2.050 INCHES MINIMUM AND 2.070 INCHES MAXIMUM
BOSS HEIGHT0.130 INCHES MINIMUM AND 0.150 INCHES MAXIMUM
MOUNTING SURFACE TO TERMINAL END DISTANCE2.408 INCHES MINIMUM AND 2.552 INCHES MAXIMUM
THREAD SERIES DESIGNATOR UNC
NOMINAL THREAD SIZE0.138 INCHES
THREAD QUANTITY PER INCH32
MANUAL ACTUATOR TYPE AND QUANTITY1 TOGGLE
ACTUATOR FUNCTION TRIP W/SEPARATE RESET
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED FUNGUS RESISTANT AND MOISTURE RESISTANT
ARC QUENCHING METHOD MAGNETIC BLOWOUT
STORAGE TYPEE ANY ACCEPTABLE
UNPACKAGED UNIT WEIGHT0.280 POUNDS
SPECIAL HANDLING FEATURE MAGNETIC
PRECIOUS MATERIAL SILVER
PRECIOUS MATERIAL AND LOCATIONTERMINALS AND NUTS AND WASHERS SILVER
FRAGILITY FACTOR MODERATELY RUGGED