NSN 5925-00-011-4576

Part Details | CIRCUIT BREAKER

5925-00-011-4576 A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see RELAY (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see RELAY-SWITCH. Excludes CIRCUIT BREAKER BOX and magneto "breaker" assemblies. See also SWITCH (as modified); and CONTROLLER.

Alternate Parts: JA1B3A152, JA1-B3-A-15-2, JA1SB3A001502N, JA1S-B3-A-0015-02N, 546802, 546802, APG17372, APG1-737-2, 5925-00-011-4576, 00-011-4576, 5925000114576, 000114576

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
59APR 20, 196700-011-457600136 ( CIRCUIT BREAKER )
REFERENCE DRAWINGS & PICTURES

SINGLE POLE TYPE

CIRCUIT BREAKER | 5925-00-011-4576, 000114576
Cross Reference | NSN 5925-00-011-4576
Part Number Cage Code Manufacturer
JA1-B3-A-15-274193EATON CORPHEINEMANN PRODUCTS
JA1S-B3-A-0015-02N74193EATON CORPHEINEMANN PRODUCTS
5468021PQF4L3 TECHNOLOGIES, INC.DBA LINK SIMULATION & TRAINING
54680236378RAYTHEON TECHNICAL SERVICES COMPANY
APG1-737-281541SENSATA TECHNOLOGIES MARYLAND, INC
Technical Data | NSN 5925-00-011-4576
Characteristic Specifications
POLE QUANTITY1
TERMINAL TYPE AND QUANTITY2 QUICK DISCONNECT, MALE
RESET METHOD MANUAL
BODY STYLE SINGLE POLE TYPE
CASE MATERIAL PLASTIC
MOUNTING FACILITY TYPE AND QUANTITY2 THREADED HOLE
MAIN CONTACT TRIPPING MECHANISM TYPE TRIP FREE
BODY LENGTH1.985 INCHES MINIMUM AND 2.015 INCHES MAXIMUM
BODY WIDTH0.745 INCHES MINIMUM AND 0.755 INCHES MAXIMUM
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH1.555 INCHES MINIMUM AND 1.565 INCHES MAXIMUM
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH1.655 INCHES MINIMUM AND 1.665 INCHES MAXIMUM
BOSS HEIGHT0.125 INCHES MINIMUM AND 0.135 INCHES MAXIMUM
MOUNTING SURFACE TO TERMINAL END DISTANCE1.875 INCHES MINIMUM AND 1.885 INCHES MAXIMUM
THREAD SERIES DESIGNATOR UNC
NOMINAL THREAD SIZE0.138 INCHES
THREAD QUANTITY PER INCH32
MANUAL ACTUATOR TYPE AND QUANTITY1 TOGGLE
ACTUATOR FUNCTION TRIP-RESET
ACTUATOR POSITION DESIGNATION AT POLE ONE
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED FUNGUS RESISTANT AND MOISTURE RESISTANT
ARC QUENCHING METHOD MAGNETIC BLOWOUT
STORAGE TYPEE ANY ACCEPTABLE
UNPACKAGED UNIT WEIGHT2.500 OUNCES
FRAGILITY FACTOR MODERATELY RUGGED