NSN 5925-00-001-3838
Part Details | CIRCUIT BREAKER
5925-00-001-3838 A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see RELAY (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see RELAY-SWITCH. Excludes CIRCUIT BREAKER BOX and magneto "breaker" assemblies. See also SWITCH (as modified); and CONTROLLER.
Alternate Parts: 7MC4340.250, 7MC43-4-0.250, 5925-00-001-3838, 00-001-3838, 5925000013838, 000013838
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | SEP 20, 1972 | 00-001-3838 | 00136 ( CIRCUIT BREAKER ) |
REFERENCE DRAWINGS & PICTURES
SINGLE POLE TYPE
Cross Reference | NSN 5925-00-001-3838
Part Number | Cage Code | Manufacturer |
---|---|---|
7MC43-4-0.250 | 82647 | SENSATA TECHNOLOGIES, INCDIV SENSATA ATTLEBORO |
Technical Data | NSN 5925-00-001-3838
Characteristic | Specifications |
---|---|
POLE QUANTITY | 1 |
TERMINAL TYPE AND QUANTITY | 2 SCREW |
RESET METHOD | MANUAL |
BODY STYLE | SINGLE POLE TYPE |
CASE MATERIAL | PLASTIC |
MOUNTING FACILITY TYPE AND QUANTITY | 1 THREADED BUSHING |
MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
BUSHING LENGTH | 0.250 INCHES NOMINAL |
BODY LENGTH | 1.781 INCHES NOMINAL |
BODY WIDTH | 0.656 INCHES NOMINAL |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 1.341 INCHES NOMINAL |
MOUNTING SURFACE TO TERMINAL END DISTANCE | 1.669 INCHES NOMINAL |
THREAD SERIES DESIGNATOR | UNS |
NOMINAL THREAD SIZE | 0.469 INCHES |
THREAD QUANTITY PER INCH | 32 |
MANUAL ACTUATOR TYPE AND QUANTITY | 1 PUSH-PULL |
ACTUATOR FUNCTION | TRIP-RESET |
ACTUATOR POSITION DESIGNATION | AT POLE ONE |
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | CORROSION RESISTANT AND FUNGUS RESISTANT |
STORAGE TYPE | E ANY ACCEPTABLE |