NSN 5920-00-190-3348
Part Details | CARTRIDGE FUSE
5920-00-190-3348 A fuse in which the element is inclosed in a cylindrical body. The element may be renewable. The terminals may be of varying types. It may contain a visual indication that the fusible element is severed, and may also provide an audible alarm through auxiliary circuitry. For noncylindrical items, see FUSE, INCLOSED LINK.
Alternate Parts: 5M.4811.220.83, FM03A250V14A, FM03A250V1-4A, FM03250V14A, FM03-250V-1/4A, MILF234193, MIL-F-23419/3, FM03250V14A, FM03250V1-4A, F02A250V0.25, 352250018785, 5920-00-190-3348, 00-190-3348, 5920001903348, 001903348
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | DEC 17, 1971 | 00-190-3348 | 00248 ( FUSE, CARTRIDGE ) |
REFERENCE DRAWINGS & PICTURES
PLUG-IN TYPE
Cross Reference | NSN 5920-00-190-3348
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 5M.4811.220.83 | D1901 | HENSOLDT SENSORS GMBHDIV SEPS |
| FM03A250V1-4A | 81349 | MILITARY SPECIFICATIONSPROMULGATED BY MILITARY |
| FM03-250V-1/4A | 81349 | MILITARY SPECIFICATIONSPROMULGATED BY MILITARY |
| MIL-F-23419/3 | 81349 | MILITARY SPECIFICATIONSPROMULGATED BY MILITARY |
| FM03250V1-4A | 81349 | MILITARY SPECIFICATIONSPROMULGATED BY MILITARY |
| F02A250V0.25 | D2598 | SIBA GMBH & CO. KG |
| 352250018785 | H0203 | THALES NEDERLANDDBA THALES LAND & JOINT SYSTEMS |
Technical Data | NSN 5920-00-190-3348
| Characteristic | Specifications |
|---|---|
| BODY STYLE | PLUG-IN TYPE |
| OVERALL LENGTH | 0.518 INCHES NOMINAL |
| TERMINAL LENGTH | 0.170 INCHES NOMINAL |
| BODY LENGTH | 0.348 INCHES NOMINAL |
| OVERALL DIAMETER | 0.250 INCHES NOMINAL |
| TERMINAL DIAMETER | 0.025 INCHES NOMINAL |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO DIAMETER | 0.100 INCHES MINIMUM AND 0.108 INCHES MAXIMUM |
| CONTINUOUS CURRENT RATING IN AMPS | 0.250 |
| MAXIMUM VOLTAGE RATING IN VOLTS | 125.0 AC AND 125.0 DC |
| CIRCUIT OVER-CURRENT INTERRUPTION TYPE | NORMAL INSTANTANEOUS |
| SHORT-CIRCUIT/INTERRUPT CURRENT RATING IN AMPS | 10000.0 |
| INTERRUPTION INDICATOR METHOD | OPAQUE BODY |
| TERMINAL SURFACE TREATMENT | NICKEL |
| FEATURES PROVIDED | NONRENEWABLE FUSIBLE ELEMENT |
| TEST DATA DOCUMENT | 81349-MIL-F-23419 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). |
| SPECIFICATION/STANDARD DATA | 81349-MIL-F-23419 TO 2 GOVERNMENT SPECIFICATION |
| TERMINAL MATERIAL | COPPER |