NSN 5915-00-058-4982

Part Details | BAND PASS FILTER

5915-00-058-4982 An item designed to pass frequencies within a specified range (band) and to suppress frequencies outside the range (band). Excludes a single inductance, or a single capacitance, or a single resistance. See COIL (as modified); REACTOR; CAPACITOR (as modified); and RESISTOR (as modified).

Alternate Parts: 535A, C38253, B740A, C38253, C-38253, 535A, 5915-00-058-4982, 00-058-4982, 5915000584982, 000584982

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
59JAN 01, 196100-058-498200209 ( FILTER, BAND PASS )
REFERENCE DRAWINGS & PICTURES

RECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE

FILTER,BAND PASS | 5915-00-058-4982, 000584982
Cross Reference | NSN 5915-00-058-4982
Part Number Cage Code Manufacturer
535A28726BULOVA TECHNOLOGIES L.L.C.DBA ENVIRONMENTAL SYSTEMS & SVCS
C3825342498DAR ELECTRONICS INCDBA NATIONAL RADIO CO
B740A56662FREQUENCY SELECTIVE NETWORKS INC
C-3825373293L-3 COMMUNICATIONS ELECTRONTECHNOLOGIES, INC.
535A03040POWER CONTROL DEVICES, INC.DBA AMERICAN TIME PRODUCTS
Technical Data | NSN 5915-00-058-4982
Characteristic Specifications
REFERENCE FREQUENCY PER FUNCTIONZZ140.0 KILOHERTZ
INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS10.0 BLANK
FREQUENCY BAND WIDTH PER FUNCTIONZZ139.875 KILOHERTZ AND ZZ140.175 KILOHERTZ
INPUT IMPEDANCE PER FUNCTION W/LOADZZ22.0 KILOHMS
OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUTZZ10.0 KILOHMS
INCLOSURE TYPE HERMETICALLY SEALED
STYLE DESIGNATOR RECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE
OVERALL HEIGHT3.000 INCHES MAXIMUM
BODY LENGTH4.500 INCHES NOMINAL
BODY HEIGHT2.500 INCHES NOMINAL
BODY WIDTH2.680 INCHES NOMINAL
MOUNTING FACILITY TYPE AND QUANTITY4 THREADED STUD
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH4.000 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH2.250 INCHES NOMINAL
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATOR UNC
NOMINAL THREAD SIZE0.164 INCHES
SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTIONZZ110.00 KILOHERTZ AND ZZ139.825 KILOHERTZ AND ZZ140.175 KILOHERTZ AND ZZ170.00 KILOHERTZ
DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELSZZ60.0 MINIMUM AND ZZ6.0 MAXIMUM AND ZZ6.0 MAXIMUM AND ZZ60.0 MINIMUM
OPERATING TEMP RANGE-10.0 TO +85.0 DEG CELSIUS
BODY MATERIAL METAL