NSN 4410-00-542-5656
Part Details | LIQUID FUEL WATER HEATER
4410-00-542-5656 An item designed for heating water by a direct-fired method, using a liquid fuel burned in a combustion chamber inclosed within itself. It may be capable of using more than one type of fuel, such as gasoline, oil, kerosine, or jet fuel. It may be incorporated with a tank as an integral or as a separate unit for storage of the water so heated. For items that use liquefied petroleum gas, see HEATER, WATER, GAS. Excludes sidearm heaters.
Alternate Parts: E559200, E5-59-200, MILH51171, 4410-00-542-5656, 00-542-5656, 4410005425656, 005425656
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
44 | JAN 01, 1963 | 00-542-5656 | 28060 ( HEATER, WATER, LIQUID FUEL ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 4410-00-542-5656
Part Number | Cage Code | Manufacturer |
---|---|---|
E5-59-200 | 81361 | EDGEWOOD CHEMICAL BIOLOGICAL CENTERECBC |
MILH51171 | 81349 | MILITARY SPECIFICATIONSPROMULGATED BY MILITARY |
Technical Data | NSN 4410-00-542-5656
Characteristic | Specifications |
---|---|
GENERAL CHARACTERISTICS ITEM DESCRIPTION | O/A 32 IN. H 15 IN. W 49 IN. LG; LOW PRESSURE ATOMIZING BURNER; FOR FUEL OIL GR 1 AND 2 PER FED SPEC VV-F-815,GASO PER MIL SPEC MIL-G-3056,JET FUEL GR JP-3 JP-4 JP-5 PER MIL SPEC MIL-J-5624,KEROSINE PER FED SPEC VV-K-211; 600 GAL WATER HEATED PER HR 100 DEG F TEMP RISE PER HR; AUTOMATICALLY CONT; 60 PSI MAX WK PRESSURE; 1 WATER CONNECTION 1 IN.-11-1/2 NPT EA INLET OUTLET; INSULATED; SKID MTD; ELEC DC 24V; ADDNL EQUIP 1 EA FUEL INLET PRESSURE GA,WATER OUTLET PRESSURE GA,WATER OUTLET TEMP GA,BLOWER MOTOR SWITCH,BURNER MOTOR SWITCH,THERMOSTATIC CONT SWITCH,FUEL INLET VALVE,WATER VALVE,WATER PRESSURE RELIEF VALVE |