NSN 4240-01-298-4140
Part Details | GAS-PARTICULATE FILTER
4240-01-298-4140 An item consisting of mechanical and chemical filters designed to eliminate from the contaminated air passing through it, biological organisms, radioactive particles, and toxic and/or irritating chemical gases and vapors likely to be used in warfare. It is designed for specific use with FILTER UNIT, GAS-PARTICULATE. It may be supplied with a FRAME,MOUNTING,GAS-PARTICULATE. It may or may not have a regulator.
Alternate Parts: ADU673E, ADU-673/E, ADU673E, ADU-673/E, ADU673E, ADU-673/E, 4240-01-298-4140, 01-298-4140, 4240012984140, 012984140
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
42 | APR 16, 1989 | 01-298-4140 | 10099 ( FILTER, GAS-PARTICULATE ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 4240-01-298-4140
Part Number | Cage Code | Manufacturer |
---|---|---|
ADU-673/E | 07878 | AERONAUTICAL AND SUPPORT EQUIPMENTTYPE/ASETDS/AFLCMC/EZSC |
ADU-673/E | 98750 | SAN ANTONIO AIR LOGISTICS CENTER |
ADU-673/E | 98752 | WARNER ROBINS AIR LOGISTICS CENTER |
Technical Data | NSN 4240-01-298-4140
Characteristic | Specifications |
---|---|
FILTRATION RATE | 18.000 CUBIC FEET PER MINUTE NOMINAL |
FILTER MATERIAL | CHARCOAL, MIL-C-13724 |
FRAME MATERIAL | ALUMINUM |
OVERALL LENGTH | 30.000 INCHES NOMINAL |
OVERALL WIDTH | 30.000 INCHES NOMINAL |
OVERALL HEIGHT | 12.000 INCHES NOMINAL |
SPECIAL FEATURES | FUNCTION: TO PROVIDE COOLED,FILTERED AIR TO PERSONNEL ON A FLIGHT LINE DURING REST PERIODS. THIS IS TO PREVENT HEAT FATIGUE. THIS UNIT FILTERS AIR THAT HAS ALREADY BEEN COOLED THROUGH AN AIR CONDITIONER. THE AIR IS DELIVERED TO A COOLING VEST OR A FACE MASK; ENVIORNMENT: DESIGNED FOR A NUCLEAR,BIOLOGICAL,CHEMICAL ENVIORNMENT; CONFIGURATION: A HOUSING WHICH CONTAINS 2 FITERS AND WHICH HAS AN INLET AND MANIFOLD; FILTERS: 2 M-48 FILTERS,NSN 4240-01-161-3710,MIL-C-13724 CHARCOAL; CONNECTOR: 8 IN. FEMALE CONNECTOR FOR AIR CONDITIONER; HOUSING MANIFOLD: UP TO 10 USERS MAY BE CONNECTED; AIR INPUT FROM AIR CONDITIONER: MUST NOT EXCEED 200 CFM; AIR OUTPUT TO EA USER: 18 CFM; AIR REGULATORS: 2 DUMP VALVES IN THE ADAPTER INLET; AUXILIARY EQUIPMENT: AIR COOLING VEST,NSN 8415-01-217-5634,AND ANY SUITABLE AIR CONDITIONER,SUCH AS NSN 4120-00-390-3541 |