NSN 4140-00-009-0233

Part Details | CENTRIFUGAL FAN

4140-00-009-0233 A nonpositive displacement mechanical device having a centrifugal fan impeller inclosed within a housing. It is designed to move air or gas over a wide range of volumes and pressures. The air or gas is drawn in axially and discharged radially or drawn in radially and discharged axially by centrifugal force through an outlet in the housing.

Alternate Parts: 9126C7015, B15J3L9, 9126C7015, 2994921, 2994921, A062642, A0-62642, 023122, DRFSMS1504CCW910WS, DRFS-MS1504CCW-910WS, DRFSMS1504CCW910WF, DRFS-MS1504CCW-910WF, A062642, 2994921, 4140-00-009-0233, 00-009-0233, 4140000090233, 000090233

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
41JUL 29, 197200-009-023304254 ( FAN, CENTRIFUGAL )
REFERENCE DRAWINGS & PICTURES

FIXED, RECTANGULAR OUTLETS

FAN,CENTRIFUGAL | 4140-00-009-0233, 000090233
Cross Reference | NSN 4140-00-009-0233
Part Number Cage Code Manufacturer
9126C701594117BAE SYSTEMS INFORMATION ANDELECTRONIC SYSTEMS INTEGRATION INC.
B15J3L919070EASTERN AIR DEVICES INCDBA EAD MOTORS
9126C701587557LOCKHEED CORPLOCKHEED ELECTRONICS CO INC
299492110001NAVAIR AND NAVSEA MANAGEDORIGINAL DESIGN ACTIVITY DWG NOT
299492153711NAVAL SEA SYSTEMS COMMAND
A0-6264282877ROTRON INCORPORATEDDBA AMETEK ROTRON
02312282877ROTRON INCORPORATEDDBA AMETEK ROTRON
DRFS-MS1504CCW-910WS82877ROTRON INCORPORATEDDBA AMETEK ROTRON
DRFS-MS1504CCW-910WF82877ROTRON INCORPORATEDDBA AMETEK ROTRON
A062642D9182ZF INDUSTRIEANTRIEBE WITTEN GMBH
2994921D9182ZF INDUSTRIEANTRIEBE WITTEN GMBH
Technical Data | NSN 4140-00-009-0233
Characteristic Specifications
STYLE DESIGNATOR FIXED, RECTANGULAR OUTLETS
WIDTH3.499 INCHES NOMINAL
LENGTH2.641 INCHES NOMINAL
OUTLET INSIDE WIDTH1.312 INCHES NOMINAL
OUTLET INSIDE HEIGHT1.250 INCHES NOMINAL
HEIGHT3.342 INCHES NOMINAL
DRIVE TYPE DIRECT
ROTATION DIRECTION FOR WHICH DESIGNED COUNTERCLOCKWISE
PRIME MOVER TYPE ELECTRIC MOTOR
SPEED ADJUSTMENTS SINGLE SPEED
PRIME MOVER DRIVE SHAFT BEARING TYPE BALL
INCLOSURE TYPE FULLY INCLOSED
AMBIENT TEMP AT FULL RATED POWER-20.0 DEG CELSIUS AND 75.0 DEG CELSIUS
ELECTRICAL CONNECTION TYPE TERMINAL BLOCK
PRIME MOVER POWER RATING8.5 WATTS
OPERATING SPEED AT RATED CAPACITY IN RPM6700.0
VOLTAGE IN VOLTS AND CURRENT TYPE115.0 AC
PHASE THREE
FREQUENCY IN HERTZ400.0
AIR FLOW RATE20.0 CUBIC FEET PER MINUTE NOMINAL
STATIC PRESSURE AT SPECIFIED AIR FLOW RATE0.5 INCHES OF WATER
MOUNTING FACILITY TYPE AND QUANTITY1 FLANGE AND 4 UNTHREADED HOLE
OUTLET LOCATION TOP
DISCHARGE DIRECTION VERTICAL UP
FEATURES PROVIDED SAFETY IMPELLER GUARD