NSN 4140-00-008-1875
Part Details | VENTILATING FAN
4140-00-008-1875 A nonpositive displacement mechanical device having either an axial or centrifugal fan impeller. It is designed to move free air or gas from indoors to outdoors or vice versa over a wide range of volumes at low pressures. It is supported by a ring, plate, or shroud or may be inclosed in a housing. It is designed for installation in a window, roof or wall opening, or the like.
Alternate Parts: 03820008001, 03820008-001, 70964007001, 70964007-001, 03820008001, 03820008-001, 4140-00-008-1875, 00-008-1875, 4140000081875, 000081875
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) | 
|---|---|---|---|
| 41 | JUL 16, 1972 | 00-008-1875 | 04262 ( FAN, VENTILATING ) | 
REFERENCE DRAWINGS & PICTURES
FIXED
 
					Cross Reference | NSN 4140-00-008-1875
| Part Number | Cage Code | Manufacturer | 
|---|---|---|
| 03820008-001 | 53178 | BULL HN INFORMATION SYSTEMS INC | 
| 70964007-001 | 53178 | BULL HN INFORMATION SYSTEMS INC | 
| 03820008-001 | 33322 | GETRONICS GOVERNMENT SOLUTIONS LLC | 
Technical Data | NSN 4140-00-008-1875
| Characteristic | Specifications | 
|---|---|
| STYLE DESIGNATOR | FIXED | 
| WIDTH | 4.449 INCHES NOMINAL | 
| LENGTH | 1.970 INCHES NOMINAL | 
| HEIGHT | 4.449 INCHES NOMINAL | 
| HOUSING INSIDE DIAMETER | 3.450 INCHES NOMINAL | 
| DRIVE TYPE | DIRECT | 
| ROTATION DIRECTION FOR WHICH DESIGNED | CLOCKWISE | 
| PRIME MOVER TYPE | ELECTRIC MOTOR | 
| SPEED ADJUSTMENTS | SINGLE SPEED | 
| PRIME MOVER DRIVE SHAFT BEARING TYPE | SLEEVE | 
| INCLOSURE TYPE | FULLY INCLOSED | 
| AMBIENT TEMP AT FULL RATED POWER | -20.0 DEG CELSIUS AND 55.0 DEG CELSIUS | 
| ELECTRICAL CONNECTION TYPE | WIRE LEAD | 
| PRIME MOVER POWER RATING | 25.0 WATTS | 
| OPERATING SPEED AT RATED CAPACITY IN RPM | 3400.0 | 
| VOLTAGE IN VOLTS AND CURRENT TYPE | 115.0 AC | 
| PHASE | SINGLE | 
| FREQUENCY IN HERTZ | B50.0$$B60.0 | 
| AIR FLOW RATE | 175.0 CUBIC FEET PER MINUTE NOMINAL | 
| STATIC PRESSURE AT SPECIFIED AIR FLOW RATE | 0.0 INCHES OF WATER | 
| FLOW DIRECTION | INWARD | 
| MOUNTING FACILITY TYPE AND QUANTITY | 8 UNTHREADED HOLE |