NSN 6685-00-411-2363

Part Details | DIAL INDICATING PRESSURE GAGE

6685-00-411-2363 An instrument designed to measure air, gas, fluid, and vapor pressure by means of an internal pressure sensitive element (bellows, bourdon tube, transducer/transmitter and the like) which transmits energy, by direct linkage, to the indicating pointer of a scale or a digital display, calibrated in units of pressure. It may include a temperature equivalent scale. For items that do not have an internal pressure sensitive element see INDICATOR, PRESSURE.

Alternate Parts: 440ASR, 6685-00-411-2363, 00-411-2363, 6685004112363, 004112363

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
66AUG 20, 196900-411-236307428 ( GAGE, PRESSURE, DIAL INDICATING )
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 6685-00-411-2363
Part Number Cage Code Manufacturer
440ASR70462BRISTOL BABCOCK INCHELICOID INSTRUMENTS DIV
Technical Data | NSN 6685-00-411-2363
Characteristic Specifications
ACTUATION TYPE SINGLE BOURDON TUBE
ACTUATING ELEMENT MATERIAL STEEL, CORROSION RESISTING
SCALE TYPE SINGLE
SCALE NAME PRESSURE
SCALE RANGE+0.000 TO +100.000 POUNDS PRESSURE PER SQUARE INCH
SCALE ACCURACYPORM 1/2 OF 1 PCT ACCURACY RATING ENTIRE RANGE
GRADUATION UNIT10.0 DEGREES
SCALE SMALLEST INCREMENT0.5 POUNDS
SCALE INSCRIPTION/BACKGROUND COLORBLACK FIGURES ON WHITE BACKGROUND
DIAL SIZE4-1/2 IN. DIA
POINTER TYPE INDICATING
ADJUSTABILITY ADJUSTABLE
POINTER COLOR BLACK
CASE MATERIAL ALUMINUM ALLOY
CASE SURFACE TREATMENT ENAMEL
OVERALL DIAMETER5.937 INCHES NOMINAL
OVERALL DEPTH2.187 INCHES NOMINAL
MATERIAL STEEL CORROSION RESISTING
BEZEL TYPENC ANY ACCEPTABLE
PROTECTIVE CRYSTAL MATERIAL GLASS
CONNECTION QUANTITY1
CONNECTION TYPE EXTERNAL
CONNECTION LOCATION LOWER
CONNECTION SIZE1/4 IN. NPT
MOUNTING METHODRY ANY ACCEPTABLE AND E ANY ACCEPTABLE
BOLT CIRCLE DIAMETER5.375 INCHES NOMINAL
MOUNTING HOLE QUANTITY3
MOUNTING HOLE DIAMETER0.218 INCHES NOMINAL
STUD QUANTITY3
STUD LOCATION
CONNECTOR TYPE VENT NOT PROVIDED
REFERENCE NUMBER DIFFERENTIATING CHARACTERISTICSAS DIFFERENTIATED BY SCALE NAME,SCALE RANGE,AND SCALE SMALLEST INCREMENT
USAGE DESIGNFOR USE W/ACETIC,ACFD,BLEACH LIQUORS,AMMONIA,CHROMATIC ACID AND OTHER CORRODANTS,EXCEPT OXYGEN AND ANY OTHER OXIDIZING AGENT