NSN 6665-01-342-7747
Part Details | RADIAC SET
6665-01-342-7747 A fixed number of components and/or items, not all having the same basic name, which are used to detect, measure and/or compute radioactivity. They may or may not indicate simultaneously.
Alternate Parts: 703233, ADM300 KIT B, ADM-300 KIT B, 6665-01-342-7747, 01-342-7747, 6665013427747, 013427747
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
66 | JUL 29, 1991 | 01-342-7747 | 07331 ( RADIAC SET ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 6665-01-342-7747
Part Number | Cage Code | Manufacturer |
---|---|---|
703233 | 96696 | CANBERRA INDUSTRIES INC. |
ADM-300 KIT B | 96696 | CANBERRA INDUSTRIES INC. |
Technical Data | NSN 6665-01-342-7747
Characteristic | Specifications |
---|---|
RADIATION RANGE PER HOUR | +0.0 TO +5.0 ROENTGENS |
DOSE RATE PER HOUR | +0.0 TO +1000.0 RAD |
ACCURACY IN PERCENT | -10.0 TO +10.0 AT FULL SCALE |
INDICATOR TYPE | HE ANY ACCEPTABLE |
DETECTING ELEMENT TYPE | B ANY ACCEPTABLE AND D ANY ACCEPTABLE |
VOLTAGE IN VOLTS AND CURRENT TYPE | 9.0 DC |
INTERNAL BATTERY ACCOMMODATION | INCLUDED |
ACCESSORY CONTROLLING AGENCY | NUCLEAR RESEARCH CORP. |
FURNISHED ITEMS | SURVEY METER P/N 702454; GUN HANDLE P/N 703231; CARRYING CASE P/N 702464; POUCH P/N 702465 AND STRAP P/N 703272 |
SPECIAL FEATURES | PORTABLE ITEM; CAN BE REPLACED BY ADM300 KIT A NSN 6665-01-363-6213 OR ADM300 KIT C NSN 6665-01-320-4712; NON-AVIATION CRITICAL SAFETY ITEM |