NSN 6635-00-476-0282

Part Details | EDDY CURRENT PROBE

6635-00-476-0282 An item with or without attaching cable designed to detect flaws, cracks and the like on surface or near surface metals. Establishes a magnetic field through the probe coil and locates the resulting magnetic disturbance in the item under test. Used in conjunction with DETECTOR, METAL FLAW, ELECTRONIC. Excludes PROD, TEST.

Alternate Parts: 6200580BH8, 6200-580BH8, 65D1111, 65D111-1, 6635-00-476-0282, 00-476-0282, 6635004760282, 004760282

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
66JUN 04, 197100-476-028236329 ( PROBE, EDDY CURRENT )
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 6635-00-476-0282
Part Number Cage Code Manufacturer
6200-580BH823910IDEAL SPECIALTY INC.
65D111-197057NAVAL AIR REWORK FACILITYNAVAIRSYSCOM HQ
Technical Data | NSN 6635-00-476-0282
Characteristic Specifications
TIP TERMINATION TYPE PROBE
TIP REPLACEABILITY FEATURE NOT INCLUDED
CONDUCTOR ATTACHMENT METHODCABLE ATTACHED BY 80-MC2M TYPE CONNECTOR
OVERALL LENGTH3.000 INCHES NOMINAL
OVERALL DIAMETER0.580 INCHES NOMINAL
SPECIAL FEATURES8 FT LG CABLE
END ITEM IDENTIFICATIONMAGNAFLUX EDDY CURRENT TESTER MODEL ED520