NSN 6110-00-104-4341

Part Details | ELECTRICAL MOTOR THERMAL-OVERLOAD PROTECTOR

6110-00-104-4341 A protective device specifically designed to prevent damage to an electrical motor due to failure of the motor to start, severe overloading of short duration, too frequent starting, high ambient temperature, high or low circuit voltages, failure of ventilation or any combination thereof. It is designed to be either automatically or manually reset. Excludes CIRCUIT BREAKEY; SWITCH (1), THERMOSTATIC; HEATER, THERMAL RELEASE; and RELAY (1), THERMAL.

Alternate Parts: 5621, 9700L0511, 9700L05-11, 9700L2011, 9700L20-11, 6110-00-104-4341, 00-104-4341, 6110001044341, 001044341

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
61JUN 19, 196800-104-434160869 ( PROTECTOR, THERMAL-OVERLOAD, ELECTRICAL MOTOR )
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 6110-00-104-4341
Part Number Cage Code Manufacturer
562192878HDT EXPEDITIONARY SYSTEMS, INC.
9700L05-1182647SENSATA TECHNOLOGIES, INCDIV SENSATA ATTLEBORO
9700L20-1182647SENSATA TECHNOLOGIES, INCDIV SENSATA ATTLEBORO
Technical Data | NSN 6110-00-104-4341
Characteristic Specifications
POLE QUANTITY2
OVERALL LENGTH3.413 INCHES MINIMUM AND 3.817 INCHES MAXIMUM
SPECIAL FEATURESONE END 0.951 IN. MIN,0.979 IN. MAX BY 0.260 IN. MIN,0.290 IN. MAX THK; TEMP SETTING OPEN 224 DEG F,CLOSED 145 DEG F; MYLAR SLEEVE ONE END; 2 TERMINALS 0.375 IN. LG OTHER END