NSN 6105-00-508-1239
Part Details | CONTROL MOTOR
6105-00-508-1239 A motor which is designed to be operated from two independent voltage sources, in such a way that variations in one voltage source will determine the direction and speed of the motor. In the alternating current type the voltages are usually applied to a split-phase stator, whereas in the direct current type, one voltage is applied to the stator and the other to the armature. Low inertia and rapid reversibility are inherent characteristics of this type of motor. See also SERVOMOTOR, AUTOMATIC PILOT.
Alternate Parts: R1102A, R110-2A, 9405051, 940505-1, 6105-00-508-1239, 00-508-1239, 6105005081239, 005081239
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
61 | JAN 01, 1963 | 00-508-1239 | 19258 ( MOTOR, CONTROL ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 6105-00-508-1239
Part Number | Cage Code | Manufacturer |
---|---|---|
R110-2A | 88818 | KEARFOTT CORPORATIONDBA KEARFOTT |
940505-1 | 82577 | RAYTHEON COMPANYDBA RAYTHEON |
Technical Data | NSN 6105-00-508-1239
Characteristic | Specifications |
---|---|
OVERALL LENGTH | 2.196 INCHES |
OVERALL WIDTH | 1.437 INCHES |
OVERALL HEIGHT | 1.437 INCHES |
MOUNTING METHOD | FACE |
MOUNTING FACILITY TYPE AND QUANTITY | 1 CLAMP COLLAR AND 4 THREADED HOLE |
MOUNTING FACILITY CIRCLE DIAMETER | 1.100 INCHES |
INCLOSURE FEATURE | TOTALLY INCLOSED |
INCLOSURE SPECIFICATION | COMMERCIAL |
CURRENT RATING METHOD | LOCKED ROTOR |
TORQUE RATING AND TYPE | 1.53 INCH-OUNCES STALLED |
TEMP RATING | 65.0 AMBIENT DEG CELSIUS AND -54.0 OPERATING DEG CELSIUS AND 125.0 OPERATING DEG CELSIUS |
COOLING METHOD | NONVENTILATED |
TERMINAL TYPE AND QUANTITY | 6 SCREW |
CONTROL FIELD VOLTAGE TYPE AND RATING IN VOLTS | 57.5 AC AND 115.0 AC |
CONTROL FIELD CURRENT RATING IN AMPS | B0.220$$B0.110 |
CONTROL FIELD IMPEDANCE RATING IN OHMS | B257.0$$B1030.0 |
CONTROL FIELD WINDING TYPE | TWO WINDINGS, SERIES CONNECTED |
ROTOR SPEED RATING IN RPM | 5300.0 SINGLE NO LOAD |
FEATURES PROVIDED | HORIZONTAL MOUNTING POSITION AND VERTICAL MOUNTING POSITION |