NSN 6105-00-500-2387

Part Details | CONTROL MOTOR

6105-00-500-2387 A motor which is designed to be operated from two independent voltage sources, in such a way that variations in one voltage source will determine the direction and speed of the motor. In the alternating current type the voltages are usually applied to a split-phase stator, whereas in the direct current type, one voltage is applied to the stator and the other to the armature. Low inertia and rapid reversibility are inherent characteristics of this type of motor. See also SERVOMOTOR, AUTOMATIC PILOT.

Alternate Parts: 1371312PC1, 6105-00-500-2387, 00-500-2387, 6105005002387, 005002387

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
61JAN 01, 196300-500-238719258 ( MOTOR, CONTROL )
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 6105-00-500-2387
Part Number Cage Code Manufacturer
1371312PC110001NAVAIR AND NAVSEA MANAGEDORIGINAL DESIGN ACTIVITY DWG NOT
Technical Data | NSN 6105-00-500-2387
Characteristic Specifications
OVERALL LENGTH4.190 INCHES
OVERALL WIDTH2.250 INCHES
OVERALL HEIGHT2.990 INCHES
MOUNTING METHOD PAD
MOUNTING FACILITY TYPE AND QUANTITY4 UNTHREADED HOLE
NOMINAL CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH1.875 INCHES
NOMINAL CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO HEIGHT1.875 INCHES
INCLOSURE FEATURE TOTALLY INCLOSED
INCLOSURE SPECIFICATION MIL-STD-108
CURRENT RATING METHOD NO LOAD
TORQUE RATING AND TYPE7.0 INCH-OUNCES STALLED
TEMP RATING80.0 AMBIENT DEG CELSIUS
COOLING METHOD AIR TO AIR COOLED
CONTROL FIELD VOLTAGE TYPE AND RATING IN VOLTS250.0 AC
CONTROL FIELD CURRENT RATING IN AMPS0.120
CONTROL FIELD IMPEDANCE RATING IN OHMS7000.0
CONTROL FIELD WINDING TYPE TWO WINDINGS, SERIES CONNECTED
ROTOR SPEED RATING IN RPM3400.0 SINGLE NO LOAD
FEATURES PROVIDED HORIZONTAL MOUNTING POSITION