NSN 6105-00-469-7976
Part Details | ALTERNATING CURRENT MOTOR
6105-00-469-7976 A motor which is designed for operation from an alternating current source. See also MOTOR, CONTROL.
Alternate Parts: 317P020, 317P020, 6K086, 5K279, 6105-00-469-7976, 00-469-7976, 6105004697976, 004697976
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
61 | JAN 06, 1971 | 00-469-7976 | 00530 ( MOTOR, ALTERNATING CURRENT ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 6105-00-469-7976
Part Number | Cage Code | Manufacturer |
---|---|---|
317P020 | 99167 | HAMILTON SUNDSTRAND CORPORATION |
317P020 | 83843 | SUNDSTRAND CORPELECTRIC POWER SYSTEMS DIV |
6K086 | 25795 | W.W. GRAINGER, INC.DBA GRAINGER |
5K279 | 25795 | W.W. GRAINGER, INC.DBA GRAINGER |
Technical Data | NSN 6105-00-469-7976
Characteristic | Specifications |
---|---|
OVERALL LENGTH | 9.840 INCHES |
OVERALL WIDTH | 6.500 INCHES |
OVERALL HEIGHT | 6.310 INCHES |
MOUNTING METHOD | FIXED BASE |
MOUNTING FACILITY TYPE AND QUANTITY | 4 SLOT |
NOMINAL CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 3.000 INCHES |
NOMINAL CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 4.880 INCHES |
INCLOSURE FEATURE | DRIPPROOF PROTECTED-15 DEG |
INCLOSURE SPECIFICATION | NEMA |
FRAME SIZE DESIGNATION | SB56Z |
CURRENT RATING METHOD | LOAD |
WINDING TYPE | INDUCTION-SPLIT PHASE |
DUTY CYCLE | CONTINUOUS |
TEMP RATING | 40.0 AMBIENT DEG CELSIUS AND 50.0 OPERATING DEG CELSIUS |
COOLING METHOD | SELF-VENTILATED |
ROTOR SPEED RATING IN RPM | 1725.0 SINGLE FULL LOAD |
FEATURES PROVIDED | HORIZONTAL MOUNTING POSITION AND VERTICAL MOUNTING POSITION |