NSN 6105-00-014-3932
Part Details | CONTROL MOTOR
6105-00-014-3932 A motor which is designed to be operated from two independent voltage sources, in such a way that variations in one voltage source will determine the direction and speed of the motor. In the alternating current type the voltages are usually applied to a split-phase stator, whereas in the direct current type, one voltage is applied to the stator and the other to the armature. Low inertia and rapid reversibility are inherent characteristics of this type of motor. See also SERVOMOTOR, AUTOMATIC PILOT.
Alternate Parts: 617459, SMB617459, 6105-00-014-3932, 00-014-3932, 6105000143932, 000143932
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
61 | MAY 06, 1968 | 00-014-3932 | 19258 ( MOTOR, CONTROL ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 6105-00-014-3932
Part Number | Cage Code | Manufacturer |
---|---|---|
617459 | 36180 | ULTRA ELECTRONICS MARITIMESYSTEMSINC DBA ULTRA |
SMB617459 | 80063 | US ARMY COMMUNICATIONS &ELECTRONICS MATERIEL READINESS |
Technical Data | NSN 6105-00-014-3932
Characteristic | Specifications |
---|---|
OVERALL LENGTH | 2.162 INCHES |
OVERALL WIDTH | 0.937 INCHES |
OVERALL HEIGHT | 0.937 INCHES |
MOUNTING METHOD | CLAMP RING |
MOUNTING FACILITY TYPE AND QUANTITY | 1 CLAMP COLLAR |
INCLOSURE FEATURE | TOTALLY INCLOSED |
INCLOSURE SPECIFICATION | COMMERCIAL |
TORQUE RATING AND TYPE | 7.0 INCH-OUNCES STALLED |
TEMP RATING | -54.0 OPERATING DEG CELSIUS AND 85.0 OPERATING DEG CELSIUS |
COOLING METHOD | NONVENTILATED |
MAXIMUM OPERATING ALTITUDE RATING | 50000.0 FEET |
TERMINAL TYPE AND QUANTITY | 6 WIRE LEAD |
CONTROL FIELD WINDING TYPE | TWO WINDINGS, PARALLEL CONNECTED |
FEATURES PROVIDED | HORIZONTAL MOUNTING POSITION AND VERTICAL MOUNTING POSITION |