NSN 5955-00-004-2035
Part Details | QUARTZ CRYSTAL UNIT
5955-00-004-2035 An item which consists of a quartz crystal resonator(s), suitably mounted in a HOLDER, QUARTZ CRYSTAL.
Alternate Parts: K3098, K309-8, 9251288, 925128-8, 99408, 99-40-8, 5955-00-004-2035, 00-004-2035, 5955000042035, 000042035
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | JUN 01, 1972 | 00-004-2035 | 00196 ( CRYSTAL UNIT, QUARTZ ) |
REFERENCE DRAWINGS & PICTURES
OVAL BODY, PIN TERMINALS
Cross Reference | NSN 5955-00-004-2035
Part Number | Cage Code | Manufacturer |
---|---|---|
K309-8 | 71034 | BLILEY TECHNOLOGIES INCORPORATED |
925128-8 | 82577 | RAYTHEON COMPANYDBA RAYTHEON |
99-40-8 | 00136 | VECTRON INTERNATIONAL, INC. |
Technical Data | NSN 5955-00-004-2035
Characteristic | Specifications |
---|---|
MODE OF OSCILLATION | FIFTH OVERTONE |
CIRCUIT RESONANCE | SERIES RESONANCE |
SHUNT CAPACITANCE IN PICOFARADS | 3.6 MINIMUM AND 5.4 MAXIMUM |
SPECIFIED FREQUENCY | 98.750 MEGAHERTZ |
FREQUENCY TOLERANCE FOR OPERATING TEMP IN PERCENT | M0.0015/P0.0015 |
OPERATING TEMP RANGE | -24.0 TO +54.0 DEG CELSIUS |
EQUIVALENT RESISTANCE VALUE IN OHMS | 40.0 NOMINAL |
DRIVE LEVEL RATING | 1.6 MILLIWATTS MINIMUM AND 2.4 MILLIWATTS MAXIMUM |
STYLE DESIGNATOR | 6 OVAL BODY, PIN TERMINALS |
OVERALL LENGTH | 0.235 INCHES MINIMUM AND 0.265 INCHES MAXIMUM |
TERMINAL LENGTH | 0.980 INCHES MINIMUM AND 1.105 INCHES MAXIMUM |
DIAMETER | 0.310 INCHES MINIMUM AND 0.340 INCHES MAXIMUM |
OVERALL DIAMETER | 0.340 INCHES MINIMUM AND 0.380 INCHES MAXIMUM |
TERMINAL DIAMETER | 0.016 INCHES MINIMUM AND 0.019 INCHES MAXIMUM |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS | 0.200 INCHES NOMINAL |
HOLDER COVER MATERIAL | METAL |
TEST DATA DOCUMENT | 81349-MILC3098 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). |