NSN 4120-00-926-1141

Part Details | AIR CONDITIONER

4120-00-926-1141 A self-contained unit designed to perform the functions of cooling, circulating, filtering, dehumidifying or otherwise processing of air. It may also be equipped to perform the additional functions of heating or humidifying. It may be the air cycle type used in aircraft or the vapor cycle type applicable to ground or aerospace equipment. Excludes ENVIRONMENTAL CONTROL UNIT, PERSONNEL, SELF-CONTAINED.

Alternate Parts: DL13214E3650, TIP0015806APR70, TIP00158-06APR70, MILA52767, MIL-A-52767, 4120-00-926-1141, 00-926-1141, 4120009261141, 009261141

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
41FEB 23, 196600-926-114106486 ( AIR CONDITIONER )
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 4120-00-926-1141
Part Number Cage Code Manufacturer
DL13214E365097403CECOM LR CENTER
TIP00158-06APR7097403CECOM LR CENTER
MIL-A-5276781349MILITARY SPECIFICATIONSPROMULGATED BY MILITARY
Technical Data | NSN 4120-00-926-1141
Characteristic Specifications
MOUNTING TYPEF$DABM
CABINET MATERIAL ALUMINUM-COPPER FREE
SURFACE TREATMENT ENAMEL
COOLANT TYPEK ANY ACCEPTABLE
COMPRESSOR UNIT TYPE CLOSED
CONDENSER COOLING TYPE AIR
POWER SOURCE ELECTRIC MOTOR
ELECTRIC MOTOR QUANTITY2
USAGE DESIGNCOMPRESSOR,FAN
CURRENT TYPE AC
VOLTAGE RATING208.0 VOLTS NOMINAL
FREQUENCY RATING400.0 HERTZ NOMINAL
PHASE THREE
COOLING CAPACITY IN BTU PER HOUR9000.0 NOMINAL
NOMINAL COOLING CAPACITY335.0 CUBIC FEET PER MINUTE
HEATING CAPACITY IN BTU PER HOUR6100.0 NOMINAL
NOMINAL HEATING CAPACITY335.0 CUBIC FEET PER MINUTE
SPECIAL FEATURESCOOLING TOWER-NOT INCL.;EVAPORATOR CONDENSER-NOT INCL.;ACCESSORIES-NOT INCL.;SGL PKG,COMPACT VERTICAL UNIT
NONDEFINITIVE SPEC/STD DATA1 TYPE AND B SIZE AND 4 CLASS